Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Immunol ; 14: 1190404, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37342321

RESUMO

Background: Luminex bead-based assays offer multiplexing to test antibodies against multiple antigens simultaneously; however, this requires validation using internationally certified reference standards. Therefore, there is an urgent need to characterize existing reference standards for the standardization of multiplex immunoassays (MIAs). Here, we report the development and validation of an MIA for the simultaneous estimation of levels of human serum immunoglobulin G (IgG) antibodies for pertussis toxin (PT), filamentous hemagglutinin (FHA), pertactin (PRN), diphtheria toxoid (DT), and tetanus toxoid (TT). Methods: The MIA was assessed using a panel of human serum samples and WHO reference standards. The WHO reference standards were also studied for suitability in the MIA. Purified antigens (PT, FHA, PRN, DT, and TT) were coupled to the spectrally unique magnetic carboxylated microspheres. The method was validated in accordance with the United States Food and Drug Administration (US FDA), European Medicines Agency (EMA), and the International Committee of Harmonization Multidisciplinary (ICH M10) guidelines, and parameters such as precision, accuracy, dilutional linearity, assay range, robustness, and stability were assessed. Method agreements with commercially available IgG enzyme-linked immunosorbent assay (ELISA) assays were also evaluated. In addition, the study assessed the level of correlation between the IgG levels estimated by the MIA and the cell-based neutralizing antibody assays for PT and DT. Results: We identified that an equimix of WHO international standards (i.e., 06/142, 10/262, and TE-3) afforded the best dynamic range for all the antigens in the MIA. For all five antigens, we observed that the back-fitted recoveries using the four-parameter logistic (4-PL) regression fits ranged between 80% and 120% for all calibration levels, and the percentage coefficient of variation (% CV) was < 20%. In addition, the difference in mean fluorescence intensity (MFI) between the monoplex and multiplex format was < 10% for each antigen, indicating no crosstalk among the beads. The MIA also showed good agreement with conventional and commercially available assays, and a positive correlation (> 0.75) with toxin neutralization assays for PT and DT was observed. Conclusion: The MIA that was calibrated in accordance with WHO reference standards demonstrated increased sensitivity, reproducibility, and high throughput capabilities, allowing for the design of robust studies that evaluate both natural and vaccine-induced immunity.


Assuntos
Vacinas contra Difteria, Tétano e Coqueluche Acelular , Difteria , Tétano , Estados Unidos , Humanos , Toxina Pertussis , Hemaglutininas , Reprodutibilidade dos Testes , Anticorpos Antibacterianos , Imunoglobulina G
2.
Methods ; 158: 33-43, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30690077

RESUMO

We describe here a magnetic bead-based multiplex (pentaplex) immunoassay (MIA) platform developed as an alternative to enzyme-linked immunosorbent assays (ELISA) used in immunogenicity testing of DTaP/TdaP vaccine in animals. MIA simultaneously measures the concentration of serum (IgG) antibodies against B. Pertussis antigens; pertussis toxin, filamentous hemagglutinin (FHA), pertactin (PRN) and tetanus (T) and diphtheria (D) toxoid in the Tdap vaccine immunized animals. Assay validation experiments were done using a panel of serum samples. The results are expressed in IU/ml using WHO reference mice serum. The standard curve was linear with 4PL logistic fit over an eight 2-fold dilution range with LOQ of 0.003, 0.022, 0.005 IU/ml for PT, FHA and PRN and 0.016 U/ml for T and D antigens indicating sensitivity. No interference was observed in monoplex versus multiplex measurements. Specificity was demonstrated by ≥90% homologous and ≤15% heterologous inhibition for all the antigens. The assay was reproducible, with a mean coefficient of variation (CV) of ≤10% for intra-assay duplicates and ≤25% for interassays using different lots of beads and analyst. Accuracy was demonstrated wherein the ratio of observed vs. assigned unitages were within 80-120%. The study suggests that the Pentaplex (MIA) platform meets all the criteria for the serological assay combination vaccines with additional advantages of high throughput, reduced sample volumes, faster analysis with reduced manpower in contrast to conventional monoplex ELISA.


Assuntos
Anticorpos Antibacterianos/isolamento & purificação , Vacinas contra Difteria, Tétano e Coqueluche Acelular/imunologia , Ensaios de Triagem em Larga Escala/métodos , Testes Sorológicos/métodos , Animais , Anticorpos Antibacterianos/sangue , Anticorpos Antibacterianos/imunologia , Antígenos de Bactérias/imunologia , Difteria/sangue , Difteria/imunologia , Difteria/microbiologia , Difteria/prevenção & controle , Ensaio de Imunoadsorção Enzimática/instrumentação , Ensaio de Imunoadsorção Enzimática/métodos , Feminino , Ensaios de Triagem em Larga Escala/instrumentação , Humanos , Imunogenicidade da Vacina , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Imunoglobulina G/isolamento & purificação , Fenômenos Magnéticos , Masculino , Camundongos , Microesferas , Modelos Animais , Sensibilidade e Especificidade , Testes Sorológicos/instrumentação , Tétano/sangue , Tétano/imunologia , Tétano/microbiologia , Tétano/prevenção & controle , Vacinas Combinadas/imunologia , Coqueluche/sangue , Coqueluche/imunologia , Coqueluche/microbiologia , Coqueluche/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...